01Before you send samples
My RNA has a RIN of 6.5. Can I still sequence it?
Maybe, but ask your provider first. Standard poly-A RNA-seq usually wants RIN 7 or higher. rRNA depletion copes better with partly degraded RNA. Also check that RIN is similar across your groups, so degradation doesn't look like biology.
Why did the provider measure less DNA than I did?
Usually because you measured with a NanoDrop and they used a fluorometer. The NanoDrop also counts RNA, free nucleotides and some contaminants.
Do I need to DNase-treat RNA before sequencing?
Yes, unless your provider does it. Leftover genomic DNA ends up as background reads in your RNA library.
What viability is "good enough"?
It depends on the core and platform, so ask. Many guidelines aim high (around 90%) and flag samples well below that. If your tissue can't reach it, talk to the core before the day, not after.
Can I fix my samples and run them later?
Some platforms and kits accept fixed cells, which takes the time pressure off the day. Check what your core supports before you choose this route.
Why did I get fewer cells than I loaded?
Every platform recovers only part of the cells loaded, and a wrong count makes it worse. Ask your core what recovery to expect.
Can Sanger see a heterozygous mutation?
Usually yes. A change carried by one of two copies shows up as two overlapping peaks at that position. It's the low-level changes, carried by only a small share of copies, that Sanger misses.
At what point is NGS cheaper?
It depends on your core's prices and on how many samples share a run. A common rule of thumb is that Sanger stops being cost-effective at around 20 targets. Ask for both quotes at your real sample count.
My core stopped offering Sanger. Now what?
Some university cores have closed their Sanger service and send samples to commercial providers instead. Ask your core which provider they recommend; many offer drop boxes or courier pick-up.
02Running your own nanopore
Is nanopore accurate enough now?
Accuracy has improved a lot with newer chemistry and basecalling models. Whether it's enough depends on your question, so check recent papers in your field that used the same chemistry.
Can I reuse a flow cell?
Some flow cells can be washed and reloaded for another run, usually with lower output. It works best when the next samples use different barcodes.
Do I need a powerful computer?
For the most accurate basecalling, a capable GPU helps a lot. Some groups basecall on a shared university cluster instead.
03When the data comes back
What's the difference between p-value and padj?
The p-value looks at one gene on its own. padj adjusts for the fact that you tested thousands of genes, so it controls how many of your "significant" genes are likely false. Use padj.
Can I use FPKM or TPM values to compare groups?
They're useful for looking at expression levels, but differential expression tools work on raw counts with their own normalization. Use the provider's DE table for group comparisons.
I got zero significant genes. Did something go wrong?
Not necessarily. It can mean a small effect, high variation between replicates, or too few replicates to detect changes. Check the PCA plot and talk to your provider or a bioinformatician.
Is higher alpha diversity always better?
No. Higher diversity is often linked with a healthy gut, but not everywhere. In the vaginal microbiome, for example, higher diversity is linked with infection (bacterial vaginosis). Compare against your own control group.
What is the difference between ASVs and OTUs?
OTUs group sequences that are about 97% similar. ASVs (from tools such as DADA2 or Deblur) keep exact sequences, so results are easier to compare between studies. Most newer pipelines use ASVs.
My PCoA groups overlap. Did the experiment fail?
Not necessarily. Each PCoA plot shows only part of the variation, and a small but real difference can still be hidden. Look at the PERMANOVA result and the dispersion test together.
Can I call DNA variants from RNA-seq alone?
Partly. RNA-seq only covers genes that are expressed in that tissue, and editing and splicing add errors. It can't replace DNA-seq, but it can support a variant you already found.
Do the DNA and RNA need to come from the same extraction?
No, but they should come from the same individual, and ideally from the same tissue piece and time point. Write down where each came from.
My DNA and RNA genotypes don't match. What now?
Check the sample sheet and labels first. A mix-up between two samples is a common cause. If two people's samples were swapped, re-pair them before any analysis.
Will my sample pass QC?